Reliable Sales and Servicing of Rice Lake Digital Scales
380 Synergy Series Digital Weight Indicator
Options
Reliable Sales and Servicing of Rice Lake Digital Scales
380 Synergy Series Digital Weight Indicator
Options
Powerful, Straightforward Operation
Utilize the 380 Synergy Series indicator for straightforward weighing systems including portable warehouse scales, material handling applications, and more. The 380 can easily mount almost anywhere, making weight data visible exactly where you need it.
The 380 Synergy is battery-powered, providing up to 100 hours of continuous use. A five-button keypad makes operation quick and simple while RS-232 and USB ports make it easy to connect to peripheral equipment.
Configurable print formats allow you to print only the most important information to your application. Optional date/time and external power supply are also available to meet the needs of your application.
Powerful, Straightforward Operation
Utilize the 380 Synergy Series indicator for straightforward weighing systems including portable warehouse scales, material
handling applications, and more. The 380 can easily mount almost anywhere, making weight data visible exactly where you need it.
The 380 Synergy is battery-powered, providing up to 100 hours of continuous use. A five-button keypad makes operation quick and simple while RS-232 and USB ports make it easy to connect to peripheral equipment.
Configurable print formats allow you to print only the most important information to your application. Optional date/time and external power supply are also available to meet the needs of your application.
Durable Construction
A stainless steel, IP66 enclosure means the 380 Synergy is dust-tight and can stand up to high-pressure water. A bright, six-digit LCD display makes weight data easy to see.
682 Synergy Series Weight Indicator
Options
682 Synergy Series Weight Indicator
Rice Lake Weighing Systems' 682 Synergy Plus Series digital weight indicator is an advanced solution with the simplicity of a basic weight indicator.
The durable 682 Synergy Series indicator is constructed with 304 stainless steel and has an IP69 ingress rating to stand up to high-pressure, high temperature washdowns found in food processing and other environments.
The 682 indicator has a bright five-inch color LCD screen and configurable softkeys for an interface that is easy to use.
Advanced Connectivity
The 682 indicator comes standard with advanced communications to take on a wide range of applications. Connections to external devices and networks are available through RS-232 and RS-485 serial ports, USB, Ethernet, fieldbus, Wi-Fi and Bluetooth®. This digital weight indicator also has a built-in web server for easy remote monitoring and process control.
Truck Weighing
The 682 indicator has an integrated truck in/out mode specifically designed for vehicle scale applications. This mode stores the transaction after each weigh-out with truck ID, gross, tare and net weights. Transactions may be printed or cleared at any time.
Power: Line voltage: 100 to 240 VAC, 50/60Hz
Optional: 9 to 23 VDC
Power Consumption: 3.2W (AC) 1 × 350 ohm load cell, 15W max;
4W 4 × 350 ohm load cells or 8 × 700 ohm load cells
Excitation Voltage: 10 VDC (± 5 VDC), 8 × 350 ohm or 16 × 700 ohm load cells
Analog Signal Input Range: -5 mV to +70 mV
Analog Signal Sensitivity: 0.3 μV/graduation minimum
1 μV/graduation recommended
A/D Sample Rate: 6.25 to 120 Hz, software selectable
Resolution: Internal: 8,000,000 counts
Display: 1,000,000
System Linearity: Within 0.01% full scale
Digital I/O: Four configurable I/O, 5V logic
Communication Ports: Two RS-232 (three-wire) RS-485/422 (two-wire or four-wire)
Micro USB (device) Ethernet TCP/IP (10/100)
Wi-Fi Bluetooth®
Annunciators: Zero, Gross/Net, Tare, Wi-Fi, Bluetooth®
Display: Five-inch LCD, 800 × 480 pixel, 500 NIT
Keys/Buttons: Flat membrane panel, tactile feel
18 buttons plus 5 softkeys and power
Dimensions: (L x W x H) 10.0 x 4.0 x 8.6 in (254 x 102 x 218 mm)
Temperature Range: Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Industrial: 14 °F to 122 °F (-10 °C to 50 °C)
Rating/Material: IP69K (IP66 with RJ45 option)
AISI 304 Stainless Steel
Weight: 6.25 lb (2.84 kg)
Warranty: Two-year limited
Approvals: NTEP CC 19-021, Class III/IIIL, 10,000d Measurement Canada AM-6121C
OIML R76 2006 A NL1 19.56R3 EU Test Certificate TC11562 cULus CE Marked UKCA
920i® Series Programmable Weight
Indicator and Controller
920i® Series Programmable Weight
Indicator and Controller
920i® Series Programmable Weight
Indicator and Controller
Flexibility. Power. Simplicity. It's all in the box.
The 920i® weight indicator and process controller blends revolutionary user interfaces, total flexibility and processing performance with the simplicity of a basic weight indicator. A crisp, highly customizable LCD graphical display, programmable softkeys and industry recognized electronics are surrounded by a virtually indestructible enclosure to create one of the industry’s most trusted weight indicators and process controllers.
Adding an entirely new dimension in flexibility for solution providers and users alike, the 920i indicator/controller brings simplified customization at a fraction of the cost of traditional process instrumentation. From tailored basic weighing to complex process automation, the 920i gives you features, programmability and power for your process.
Power: AC voltages: 100 to 240 VAC
Frequency: 50/60 Hz
DC voltages: 12 to 24 VDC
Power Consumption:
AC: 25W (universal) or 65W (others)
DC: 25W for all models
Excitation Voltage:
10 VDC (+/- 5 VDC)
16 × 350 ohm or 32 × 700 ohm load cells per A/D card
Analog Signal Input Range:
-45 mV to +45 mV
Analog Signal Sensitivity:
0.3 μV/graduation minimum at 7.5 Hz
1.0 μV/graduation recommended
A/D Sample Rate:
7.5 to 960 Hz, software selectable
Resolution:
Internal: 8,000,000 counts
Display: 1,000,000
System Linearity:
± 0.01% full scale
Digital I/O: Six I/O channels on CPU board;
Optional 24-channel I/O expansion boards
Communication Ports:
Four ports on CPU board support up to 115,200bps
Port 1: Full duplex RS-232
Port 2: RS-232 with CTS/RTS; PS/2 keyboard interface or USB type A and B connectors
Port 3: Full duplex RS-232, 20mA
Port 4: Full duplex RS-232, 2-wire RS-485, 20mA
Optional dual-channel serial expansion boards
Channel A: RS-232, RS-485, 20 mA
Channel B: RS-232, 20 mA
Display:
(W × H)
4.6 × 3.4 in (116 × 86 mm),
320 × 240 pixel
LCD module with adjustable contrast
Transmissive display
Transflective display (optional)
Keys/Buttons:
27-key membrane panel, tactile feel, PS/2 or USB port for external keyboard connection Temperature Range:
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Operating: 14 °F to 122 °F (-10 °C to 50 °C)
Rating/Material:
NEMA Type 4X, Type 12, IP66
Stainless steel
Weight:
Universal enclosure: 9.5 lb (4.3 kg)
Wall mount enclosure: 23.0 lb (10.4 kg)
Panel mount enclosure: 8.5 lb (3.9 kg)
Deep universal: 11 lb (5.0 kg)
Warranty:
Two-year limited
EMC Immunity: 10 V/m
Approvals: NTEP CC 01-088, Class III/IIIL 10,000d
Measurement Canada AM-5426,
Class III/III HD 10,000d
OIML R76/2006-A-GB1-19.08
EU Test Certificate TC11584
UL/cUL Listed (Universal, Deep Universal and Wall Mount)
cULus Recognized (Panel Mount)
cULus Listed 508A (Custom Wall Mount)
CE Marked
1280 Enterprise Series Programmable
Weight Indicator and Controller
1280 Enterprise Series Programmable
Weight Indicator and Controller
Power:
AC voltages: 100 to 240 VAC; 50/60 Hz
DC voltages: 11 to 30 VDC
Power Consumption:
60W
Excitation Voltage:
10 VDC (+/- 5 VDC)
16 × 350 ohm or 32 × 700 ohm load cells per A/D card
Analog Signal Input Range:
-60 mV to 60 mV
Analog Signal Sensitivity:
0.3 μV/graduation minimum at 7.5 Hz to 120 Hz
1.0 μV/graduation recommended
A/D Sample Rate:
7.5 to 960 Hz, software selectable
Resolution:
Internal: 8,000,000 counts
Display: 1,000,000
System Linearity
± 0.01% full scale
Digital I/O:
Eight I/O channels on CPU board
Optional 24-channel I/O expansion boards
Communication Ports:
Port 1 & 2: Full duplex RS-232 with CTS/RTS, RS-422/485
Baud rate: 1200 to 115200
Port 3: USB 2.0 Device (Micro)
USB host: (2) Type A connectors max 500 mA
Ethernet: Wired 10/100 Auto-MDX
Ethernet: Wireless 802.11 b/g/n 2.4GHz
Onboard:
Selectable filters: Three stage, Adaptive or Damping
Embedded Linux® OS
8 GB eMMC (system use)
1 GB DDR3 RAM
460 MB onboard database (SQLite) storage
Up to 32 GB micro SD card (sold separately)
Display:
Seven-inch, 800 × 480 pixel, 500 or 1,000 NIT
Twelve-inch, 1280 × 800 pixel, 1,500 NIT
Keys/Buttons:
22-key membrane panel, tactile buttons, on-screen keyboard for text and numeric entry, USB port for flash drive, keyboard and printer
Temperature Range:
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Operating: -4 °F to 131 °F (-20 °C to 55 °C)
Rating/Material:
Universal: IP69K
Wall Mount: IP66
Panel Mount: IP69K, NEMA Type 4X and 12
Stainless steel 304 enclosure
Weight:
Universal enclosure: 11 lb (4.9 kg)
Panel mount enclosure: 8 lb (3.6 kg)
Wall mount enclosure: 23 lb (10.4 kg)
Panel mount 7 in touch-only: 7 lb (3.1 kg)
Panel mount 12 in touch-only: 10 lb (4.5 kg)
Warranty:
Two-year limited
EMC Immunity:
10 V/m
Approvals:
NTEP CC 15-001/Class III/IIIL 10,000d
Measurement Canada AM-5980C,
Class III/III HD 10,000d
OIML R76/2006-A-NL1-19.23
Class III/IIII 10,000d
EU Test Certificate TC8596
UL/cUL Listed (Universal, Wall Mount)
UL/cUL Recognized (Panel Mount)
CE Marked
iQUBE²® Digital Diagnostic Junction Box
Applications
iQUBE²® Digital Diagnostic Junction Box
Applications
Identify Problems Before They Happen
Rice Lake Weighing Systems’ iQUBE2® digital diagnostic junction box compares the output of each load cell to adjacent load cells, ensuring optimal performance and warning operators of weight irregularities. iQUBE2 converts any analog load cell system into a modern digital system, without replacing individual load cells.
Enhance the Performance of Any Scale System
iQUBE2 is ideal for systems using single or multiple scales with two or more load cells. Floor scales, hopper scales, tank scales, vehicle scales and dosing systems can all benefit from an upgrade to the iQUBE2 digital diagnostic junction box system.
With accelerated data transfer, batching and dosing applications can efficiently achieve target weights when speed and accuracy are critical.
Instant Alerts and Cell Emulation
Diagnostics can be viewed on the user interface and an email alert is sent in the event of a component error. When a load cell fails, the cell emulation feature calculates weight based on known comparisons to functional load cells, keeping your scale functional until the load cell can be replaced.
Voltage Input:
115/230 VAC power supply DC/DC converter for 9 to 36V
6 to 12 V DC to CPU
Analog Signal Input Range:
-78 to +78 mV
Analog Signal Sensitivity:
0.3 uV/grad at 30 Hz
0.5 uV/grad at 100 Hz
1.2 uV/grad at 500 Hz
A/D Sampling Rate:
2.5 to 500 Hz (selectable)
Digital I/O:
Four per card, for push-button operation, setpoint control or cell status
Communication Ports:
RS-232/RS-422
Load Cell Inputs:
Four channels per board
up to four networked boards
Load Cell Excitation:
5 V DC, 57 mA maximum per channel
Temperature Range:
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Operating: -13 °F to 140 °F (-25 °C to 60 °C)
Storage: -13 °F to 158 °F (-25 °C to 70 °C)
Rating/Material:
Polycarbonate (NEMA Type 4X) enclosure with overlapping solid cover, stainless steel screws
Fiberglass reinforced polyester
(NEMA Type 4X) enclosure with overlapping solid cover, stainless steel screws
Stainless steel (NEMA Type 4X) enclosure with hinged cover
Warranty:
Two-year limited
Approvals:
NTEP 03-032A1
Measurement Canada AM-5561
cULus E151461
CE Marked